Hands On
8 Results
- Hands On
Enhanced cardiac device management utilizing the random EGM: A neglected feature of remote monitoring
Heart RhythmVol. 13Issue 2p602–608Published online: September 29, 2015- Sylvain Ploux
- Romain Eschalier
- Niraj Varma
- Philippe Ritter
- Nicolas Klotz
- Michel Haïssaguerre
- and others
Cited in Scopus: 8Remote monitoring (RM) of cardiac implantable devices is rapidly becoming the standard of care for implantable cardiac device follow-up. - Hands On
Prevention of phrenic nerve injury during interventional electrophysiologic procedures
Heart RhythmVol. 11Issue 10p1839–1844Published online: June 18, 2014- Marcin Kowalski
- Kenneth A. Ellenbogen
- Jayanthi N. Koneru
Cited in Scopus: 33- Video
- Audio
The advent of innovative, potent ablative technologies and the adoption of endo–epicardial approaches to treat various arrhythmias have engendered a need for developing strategies to prevent collateral damage to critical structures such as the phrenic nerve (PN) and the esophagus during percutaneous electrophysiologic interventions. Here we detail phrenic nerve injury (PNI) prevention strategies during atrial fibrillation (AF), atrial tachycardia (AT), and ventricular tachycardia (VT) ablation. PNI is more common on the right side because of the anatomic course of the nerve and the greater preponderance of AF and AT ablations. - Hands On
Safety and prevention of complications during percutaneous epicardial access for the ablation of cardiac arrhythmias
Heart RhythmVol. 11Issue 9p1658–1665Published online: June 5, 2014- Han S. Lim
- Frédéric Sacher
- Hubert Cochet
- Benjamin Berte
- Seigo Yamashita
- Saagar Mahida
- and others
Cited in Scopus: 27Since its introduction, percutaneous epicardial access is increasingly being performed to facilitate catheter ablation of ventricular tachycardias (VTs) with epicardial circuits, difficult cases of idiopathic VTs, focal atrial tachycardia, and accessory pathways that cannot be successfully targeted endocardially.1 A thorough understanding of the clinical anatomy and potential complications is vital in order to perform a safe procedure.2 In this article, we present the clinical anatomy related to epicardial access, the technique of performing a subxiphoid epicardial puncture, and various measures to prevent complications. - Hands on
How to perform ventricular tachycardia ablation with a percutaneous left ventricular assist device
Heart RhythmVol. 9Issue 7p1168–1176Published online: February 10, 2012- Marc A. Miller
- Srinivas R. Dukkipati
- Jacob S. Koruth
- Andre d'Avila
- Vivek Y. Reddy
Cited in Scopus: 26A majority of patients with structural heart disease and scar-related ventricular tachycardia (VT) have fast, hemodynamically unstable VT.1 In fact, up to one-fifth of the patients have only unstable VT, which precludes detailed activation and entrainment mapping.2 In addition, even in those with well-tolerated VT, procedural success can be complicated by acute heart failure as a consequence of prolonged episodes of induced VT and intravascular volume expansion; and one consequence of this acute decompensated heart failure is a significant increase in the short-term morbidity and mortality of the procedure. - Regular issue Hands on
Management of hemopericardium related to percutaneous epicardial access, mapping, and ablation
Heart RhythmVol. 8Issue 10p1652–1657Published online: April 4, 2011- Jacob S. Koruth
- Andre d'Avila
Cited in Scopus: 17Percutaneous epicardial access (Figs. 1A and 1B) has gained wide acceptance as an interventional technique to access the pericardial space. Since its initial description1 in targeting epicardial circuits of ventricular tachycardia (VT) in patients with Chagasic cardiomyopathy, percutaneous epicardial access and ablation has come to play an important role in interventional electrophysiology. This technique has been recognized as a vital addition to catheter ablation of certain cardiac arrhythmias and for the delivery of newer investigational devices such as epicardial suture ligation of the left atrial appendage. - Hands on
Recording and interpreting unipolar electrograms to guide catheter ablation
Heart RhythmVol. 8Issue 5p791–796Published online: December 29, 2010- Usha B. Tedrow
- William G. Stevenson
Cited in Scopus: 37Electrophysiology laboratories commonly use closely spaced bipolar recordings for mapping. However, unipolar recordings have some useful features that can provide additional complimentary information, provided the limitations of these recordings and the particular recording techniques are recognized. - Hands-on
Implantable cardioverter-defibrillators in congenital heart disease: 10 programming tips
Heart RhythmVol. 8Issue 3p480–483Published online: November 8, 2010- Paul Khairy
- Fadi Mansour
Cited in Scopus: 22Advances in cardiac care of the young have given rise to a growing and aging population of patients with congenital heart disease. Despite remarkable improvements in overall survival, sudden cardiac death remains the most common cause of late mortality. As a result, implantable cardioverter-defibrillators (ICDs) are increasingly used in this heterogeneous patient population. Tetralogy of Fallot and transposition of the great arteries are the most prevalent subtypes of congenital heart disease in ICD recipients. - Hands on
How to troubleshoot the electroanatomic map
Heart RhythmVol. 7Issue 7p999–1003Published online: March 29, 2010- Kyoko Soejima
Cited in Scopus: 8An electroanatomical mapping system is a useful tool for complex arrhythmia ablation. The system reconstructs the precise 3-dimensional chamber of interest with electrical and anatomical information. There are several technical aspects that physicians should be aware of to maximize its efficacy. This review provides relevant information on troubleshooting of the mapping system.